Dental Supplies - Buy Dental Supply - Us Dental Depot Inc
TO ORDER 1 954 874 6325
Fort Lauderdale FLORIDA USA ARGENTINA (54) 11 5258 7148
CORDOBA (54) (351) 569-1409
COLOMBIA (57) 1 489 9051
PERU (51) 1 705 53 71
BRAZIL (55) 11 3711 9401
Canister For NSK (ECCO)
| Code | Name | Price | |
|---|---|---|---|
| 112344 | ECCO - 9000S Std Push Button [More info] |
u$s 120.00 |
|
| 112343 | ECCO - 9000T Torque Push Button [More info] |
u$s 120.00 |
|
| 101963 | ECCO - Cart for ECCO-Lab Hgh Speed HP [More info] |
u$s 111.06 |
|
| 112332 | ECCO - HealthCo Push and Swivel [More info] |
u$s 120.00 |
|
| 112347 | ECCO - Kinetic Viper Lg Pushbut [More info] |
u$s 96.00 |
|
| 112345 | ECCO - Kinetic Viper Sm Pushbut [More info] |
u$s 96.00 |
|
| 112346 | ECCO - Kinetic Viper Std Pushbut [More info] |
u$s 96.00 |
|
| 112333 | ECCO - Nl65 Mini Push Button [More info] |
u$s 124.80 |
|
| 112334 | ECCO - Nl65 Std Push Button [More info] |
u$s 124.80 |
|
| 112335 | ECCO - Nl65 Torque Push Button [More info] |
u$s 124.80 |
|
| 112336 | ECCO - NL75/85 Mini Push Button [More info] |
u$s 136.00 |
|
| 112337 | ECCO - NL75/85 Std Push Button [More info] |
u$s 136.00 |
|
| 112338 | ECCO - NL75/85 Torque Push Button [More info] |
u$s 136.00 |
|
| 112339 | ECCO - NL95 Mini Push Button [More info] |
u$s 136.00 |
|
| 112340 | ECCO - NL95 Std Push Button [More info] |
u$s 136.00 |
|
| 112341 | ECCO - NL95 Torque Push Button [More info] |
u$s 136.00 |
|
| 102481 | ECCO - Replacement Cartridge for CA [More info] |
u$s 18.90 |
|
| 112342 | ECCO - Safco Excel Push Button [More info] |
u$s 96.00 |
|
| 101922 | ECCO - Turb Ceram for AIR-P-2H Japan [More info] |
u$s 68.24 |
Shamrock
Dental Company Inc.
Handpiece Sales & Repair Specialists
LUBRICATION INSTRUCTIONS FOR HIGH & LOW SPEED HANDPIECES
1 AFTER USE. REMOVE BUR & WIPE THOROUGHLY WITH ALCOHOL ONLY
2. SPRAY LUBE INTO AIRLINE (I full second), EZ Lube One Step Dropper Bottle OR USE 3 DROPS WITH DROPPER BOTTLE
NOTE:
- Kavo Multiflex
- Use Multiflex nozzle on lube can Star Swivel type
- Spray in half moon hole inside Handpiece.
3. INSERT BUR AND RUN HANDPIECE FOR 30 TO 45R SECONDS, UNTIL NO LUBE IS VISIBLE. IF LUBE EXISTS IN HEAD AND IS BLACK IN COLOR, REPEAT PROCEDURE.
DO NOT RUN HANDPIECE WITHOUT A BUR.
4. REMOVE BUR, WIPE OFF EXCESS LUBE WITH ALCOHOL ONLY BAG IN AUTOCLAVE POUCH
-DO NOT -
* Use chemical disinfectants or ultrasonic cleaners
* Remove turbine from handpiece for cleaning purposes
* Immerse handpiece in any solvent or solution
-DO?
* Follow instructions on ALL purge units, check periodically
for dispensing of solution and proper air pressure of unit.
* Drain air compressor tank (if applicable) every 2 months to SEE STERILIZATION PROCEDURES insure clean dry air.
* CALL for instructions on lubrication of low speed attachments. All manufacturers require different procedures.
STERILIZATION PROCEDURES
For High and Low Speed Handpieces
WHEN USING: * AUTOCLAVE * CHEMICLAVE * CASSETTE UNITS
1. INSERT PROPERLY LUBRICATED HANDPIECE IN STERILIZATION POUCH (POUCH MUST HAVE PAPER ON AT LEAST ONE SIDE)
2. LOAD IN THE STERILIZER WITH CELLOPHANE SIDE DOWN IN TRAY.
3. REMOVE FROM THE STERILIZER IMMEDIATELY AFTER COMPLETE CYCLE. ALLOW TO COOL.
- DO NOT ?
* STERILIZE HANDPIECE WITHOUT RUNNING & EXPELLING LUBE.
* USE NYCI.AVE OR ALL CELLOPHANE BAGS. * S I ERILIZE AT TEMPERATURE ABOVE 275° F OR 135° C.
* USE DRY HEAT STERILIZERS
* REMOVE IIANDPIECE FROM STERILIZER PRIOR TO DRYING CYCLE
LARGEST CAUSE OF PREMATURE
TURBINE & MOTOR FAILURE
A) LUBRICATING & STERILIZING WITHOUT RUNNING HANDPIECE, LUBE BUILD UP, MIXED WITH DEBRIS IN TURBINE OR ROTOR IN LOW SPEED. DESTROYS BEARING RETAINER IN HIGH SPEED & CAUSES SWELLING OF VANES IN I.OW SPEED. BY FAR THE #I CAUSE
B) RUNNING HANDPIECE IN EXCESS OF MFG. RECOMMENDATIONS
C) SPRAYING HANDPIECE WITH DISINFECTANT PRIOR TO STERILIZING
CHECK YOUR MANUAL FOR PROPER AIR PRESSURE OR CAL!. US. NOTE: UNIT PRESSURE GAUGES ARE NOT ACCURATE, WE WILL ADVISE YOU ON HOW TO COMPENSATE FOR YOUR PARTICULAR HANDPIECE.
FOR YOUR INFORMATION
THROUGH THE YEARS, MANUFACTURERS HAVE HAD MIXED OPINIONS ON THE NECESSITY OF LUBRICATING AFTER STERILIZATION. WITH THE ADVENT OF THE NEW LUBRICATION PRODUCTS ON THE MARKET MOST ARE NOW SAYING, if IS NOT NECESSARY TO LUBRICATE AFTER STERILIZATION" BECAUSE OF THE MANY DIFFERENT MAKES AND MODELS OF HANDPIECES ON THE MARKET TODAY. WE RECOMMEND THAI YOU FOLLOW THE MANUFACTURERS ADVICE ON THIS MATTER. CALL US AND WE WILL ADVISE YOU ACCORDINGLY, BASED ON YOUR INSTRUMENT. HAVING PROBLEMS? FREE ADVISE AVAILABLE FROM YOUR HANDPIECE REPAIR SPECIALISTS.
Telephone 800.367.8979 ? Local 727.367.3679 ? Fax 727.367.9751 ? shamrockdental@juno.com
1490 Pasadena Ave. South. South Pasadena FL 33707





You might also be interested in :
Reviews
Overall Rating
Write a review
Be the first to review this products
Evaluación total
Escriba un comentario
Sea el primero en comentar estos productos
Classificação
Escreva um comentário
Seja o primeiro a comentar estes produtos
TO ORDER 1 954 874 6325
Fort Lauderdale FLORIDA USA ARGENTINA (54) 11 5258 7148
CORDOBA (54) (351) 569-1409
COLOMBIA (57) 1 489 9051
PERU (51) 1 705 53 71
BRAZIL (55) 11 3711 9401
6555 NW Powerline Rd suite # 211-212 - Fort Lauderdale 33309 USA
(0) View Cart
(0) View Cart



English
Español
Português